Class 4 blade airtightness and ATC2 casing airtightness certified according to EN 1751 (formerly Class C)
Ideal for cleanrooms and high-containment laboratories
Very low upstream/downstream leakage rates
RI
- Rectangular
- Rectangular


Description
The RI shut-off damper is a high-airtightness damper certified to Class 4 blade airtightness and ATC2 casing airtightness (formerly Class C) in accordance with EN 1751. It is specifically designed to isolate sections of ventilation ductwork in sensitive installations and environments with stringent hygiene requirements.
Thanks to its reinforced design and outstanding airtightness performance, the RI damper is ideally suited to cleanrooms, Biosafety Level 4 (BSL-4) laboratories, pharmaceutical facilities, healthcare environments, and other critical HVAC applications.
Manufactured from galvanized steel or stainless steel, the RI damper provides effective isolation of ventilation systems while significantly reducing upstream/downstream air leakage and pressure losses.
The RI damper is particularly suitable for small-size HVAC ductwork requiring maximum airtightness and precise airflow control.
Characteristics
- Type: High-airtightness shut-off damper
- Function: Ventilation ductwork shut-off
- Minimum size: W 200 × H 180 mm
- Maximum size: W 700 × H 695 mm
- Blade airtightness: Class 4 according to EN 1751 (leakage rate: 0.71 l·s⁻¹·m⁻² at 500 Pa)
- Casing airtightness: ATC2 according to EN 1751 (formerly Class C)
- Maximum operating pressure: 1,200 Pa
- Operating temperature range: -20°C to +80°C
- Materials: Galvanized steel or stainless steel
- Actuation: Electric or pneumatic
Performance
Airtightness
- Blade airtightness: Class 4 according to EN 1751
- Casing airtightness: ATC2 according to EN 1751 (formerly Class C)
Pressure rating
The RI damper is designed to withstand differential pressures of up to 1,200 Pa with a 1,000 mm blade length in the galvanized steel version.
Operating temperature range
- Standard: -20°C to +80°C
Applications
- Nuclear facilities
- Cleanrooms
- Biosafety Level 4 (BSL-4) laboratories
- Pharmaceutical industry
- Operating theatres
- Healthcare environments
- Electronics industry
- Critical HVAC systems
- High-airtightness HVAC systems
- Ventilation ductwork shut-off
Options
RAL colour available on request
Class 4 blade airtightness and ATC2 casing airtightness certified according to EN 1751 (formerly Class C)
Ideal for cleanrooms and high-containment laboratories
Very low upstream/downstream leakage rates
Need help?
Need help finding the right solution for your needs?
Our teams are available Monday to Thursday from 8 a.m. to 5:30 p.m. and Friday from 8 a.m. to 4:30 p.m.